PROICELESS KIT
Drop ice from your wash for good. A multi-stage heat-exchange system chills wash water to 32–38°F. No ice runs, no dilution, no mess.
Built to order · Configured to your line · Financing available
WHAT'S INSIDE
Choose your wash vessel, then match the chiller, heat exchanger, and agitator to your line.

Air-Cooled Chiller
The refrigeration core that runs the closed-loop chill. No ice to buy.

Heat Exchanger
A high-surface exchanger pulls heat out of the wash water across the cascade.

Stainless Reservoir
Food-grade stainless (per supplier spec) holds and recirculates the chilled water.
Technical Specifications
| Specification | Value | Detail |
|---|---|---|
| Target Wash Temp | 32–38 | °F |
| Hold Accuracy | ±0.5 | °F |
| Heat-Exchange Stages | 5 | stage cascade |
| Recirculation | Continuous | closed loop |
| Ice Required | None | zero sourcing |
| Recurring Ice Cost | $0 | zero resupply |
| Setup | Quick-connect commissioning | standard wash vessel |
Five Stages, One Steady Temperature
Water cascades through five heat-exchange stages and holds 32–38°F all cycle — no ice, no drift.

Water Intake
Tap water enters the chiller at ambient temperature through the intake valve.
Pre-Cool Stage
First heat exchanger drops water temp to ~50°F using the refrigeration circuit.
Deep Chill
Secondary exchanger brings water to target temp (32–38°F) with ±0.5°F accuracy.
Recirculation
Chilled water continuously recirculates through the agitator, maintaining consistent temp throughout the wash.
Drain & Recovery
Post-wash drain with heat recovery pre-warms the next batch cycle, reducing energy consumption.
Consistency Ice Can't Match
- Cut Input Costs — Stop buying ice for every wash. It cuts a recurring ice cost from your operation, and at commercial volume that adds up.
- Steady Temperature — Ice drifts as it melts. The kit holds ±0.5°F from the first minute to the last, so your fine material stays protected.
- Faster Turnaround — No ice to source, no waiting for water to reach temp. Start the wash right away and run more batches per day.
- Continuous Recirculation — A closed-loop pump moves chilled water through the wash the whole cycle, so temp holds from the first pull to the last.
- Heat Recovery — The post-wash drain recovers heat to pre-warm the next batch, which trims your energy draw.
- Quick-Connect Commissioning — Quick-connect fittings and a set-and-hold controller commission the system onto any standard wash vessel.
Everything to Run Iceless, Day One
Chiller, pump, lines, controller, and fittings — it commissions onto a standard wash vessel with quick-connect fittings.
| Component | Description |
|---|---|
| Chiller Unit | Multi-stage heat-exchange core |
| Recirculation Pump | Continuous closed-loop flow |
| Insulated Lines | Quick-connect supply & return |
| Digital Controller | Set-and-hold temperature display |
| Fittings & Hardware | Fits standard wash vessels |
| Setup Guide | Step-by-step commissioning |
Common Questions
What temperature does the kit hold?
The kit chills and holds wash water at a target of 32–38°F within ±0.5°F for the full cycle, so temperature stays consistent from the first pull to the last.
How does going iceless save money?
You stop buying ice for every wash. Those recurring ice costs add up quickly at commercial volume.
What water source does it need?
A standard cold-water supply is all it needs. The chiller takes water in at ambient temperature and cascades it through five heat-exchange stages down to target temp.
Will it fit my existing wash vessel?
Yes. The kit uses quick-connect fittings and a closed recirculation loop that commissions onto standard wash vessels.
What maintenance is involved?
Maintenance is minimal — periodically flush the recirculation lines between runs. The refrigeration circuit is sealed, so there's no ice handling or daily resupply.
What's the lead time and is financing available?
Each package is built to order and configured to your line, so our engineers return lead time with your quote. Financing is available for qualified buyers — see our financing options or ask our team.
Ice-less Package Configurator
Ice-less Package Configurator
Built to OrderGet the Ice Out of Your Wash Room
It's the first cold morning and nobody's running for ice: the controller already reads 34°F, the loop is holding, and the first batch is washing while the store two towns over is still closed. Steady temperature, no ice bills, more batches per day — designed and built by one team in Lake Forest, California, and backed by a 1-year limited warranty.